ITEM CODE: SKU-137
Model: Olympus IX71
Shipping Cost: Free USA Shipping.
SOLD
Main Features:
- Frame Marking: Model IX71S8F-3
- 6-Position Fluorescence Reflector Turret.
- 6-Position Objective Nosepiece.
- Eyepieces: WHN10X/22 High Eyepoint with ability to use eyeglasses when viewing.
- Rubber cupping eyeguards with ability to block out extraneous illumination for better fluorescence viewing. We are including a brand-new pair.
- Side photo port. Allows 100% light to eyepieces or 20% light to eyepieces and 80% to side port.
- Magnification Changer built into frame: 1x/1.6x.
- Full mechanical XY movement stage. Right hand. This is not the cheap version that has a slider over a fixed platform.
- Original Olympus 3mm hex screwdriver with 1.5mm hex screws for centering phase rings in condenser.
- Included all needed power cords.
- DOES NOT INCLUDE CAMERA. Camera is shown in images to demonstrate how one can be connected.
- Fluorescence Illumination:
- HBO 100 fluorescence lamp housing and power supply. This is 110 V only. We can provide 220 V, but at additional cost..
- Reflected Light Vertical Illuminator. Olympus brochure says this is 20% brighter than the IX70 version.
Transmitted Illumination:
- 100W Halogen Transmitted Illumination Pillar. Ability to tilt back 30 degrees.
- Turret style rotary condenser N.A. 0.55, with settings: PhL, PhC, Ph2, BF.
- Transmitted Light Power Supply: TH4-100. This is 110 V only. We can provide 220 V, but at additional cost..
- Transmitted Light Filters: LBD-IF light balancing daylight interference filter and frosted filter.
- Halogen Lamp Housing: 12V-100W.
Fluorite Objective Lenses:
- 4x – UPlanFl N 4x/0.13, PhL, Infinity/-. FN26.5. UIS2. Phase.
- 10x – CPlanFl N 10x/0.30, PhC, Infinity/-. FN22. UIS2. Phase.
- 20x – LCAch 20x/0.40, PhC, Infinity/1. Phase. Rated for 1 mm thick petri dish.
- 20x – LUCPlanFl N 20x/0.45, Infinity/0-2. FN22. Correction Collar to adjust from zero to 2mm thickness of petri dish or flask bottom. (Not phase).
- 40x – LUCPlanFl N 40x/0.60, Ph2, Infinity/0-2. FN22. Correction Collar to adjust from zero to 2mm thickness of petri dish or flask bottom. Phase.
- Note that you have phase contrast on all these objective magnifications: 4x, 10x, 20x, 40x. Most units are not configured with phase on everything so this is a bonus.
- You also have two different 20x objectives. The best objectives for fluorescence are going to be the non-phase. So we have included both a regular phase and a non-phase fluorite objective 20x.
- Both the 20x and 40x Fluorite objectives have correction collars for adjusting to the varying bottom vessel thicknesses.
Three Dichroic Fluorescence Filter Cubes:
- DAPI, FITC, TRITC.
- All three filters were tested with fluorescence and provided excellent quality imaging.
User Manual and Instructions:
Click this link: Olympus IX71 Inverted Microscope Brochure
Click this link: Olympus IX71 Inverted Microscope Manual